Stiebel Eltron DHE 18 AU
Electric Instantaneous Water Heater 19.4kW 3 Phase
Stiebel Eltron DHE 18
Model 202658
Typically installed under benches or in cupboards, our small capacity electric units are designed to fit into the tightest spaces.
DHE instantaneous water heater – an unfailing guarantee of hot water at exactly the right temperature.
The fully electronic DHE instantaneous water heater provides hot water at the exact temperature you have set – every time. 4i technology guarantees that any factors which would change the outlet temperature are compensated for. This way you can enjoy a shower in comfort, even when someone is washing their hands at the adjacent washbasin.
Top-quality in operation too.
Due to the special haptic rotary selector, the appliance is very easy to operate: settings and adjustments are intuitive and take very little time. The set water temperature, ECO level and current power consumption can be seen clearly and concisely on the illuminated multifunction display. Energy consumption, flow rate, time, status and service display can be checked in the lower area.
Technical Data
| Model number | DHE 18 AU | DHE 27 AU |
| Rated output (415V) | 19.4kW | 28kW |
| Rated current (415V) | 27Amp | 40Amp |
| Phases | 3/PE | 3/PE |
| Electrical installation | As per AS/NZS3000 | |
| Installation requirements | AS/NZS3500.4.2 & local requirements | |
| Switch on flow rate (minimum flow rate required to switch on the water heater) | 2.5L/min | 2.5L/min |
| Max. permissible pressure | 1 MPa | 1 MPa |
| Temperature adjustment | 20-60°C | 20-60°C |
| IP Rating | IP25 | IP25 |
| Height | 466mm | 466mm |
| Width | 225mm | 225mm |
| Depth | 116mm | 116mm |
| Weight (filled with water) | 3.2kg | 3.2kg |
| Colour | white | white |
| Nominal capacity | 0.4L | 0.4L |
| Approvals | WaterMark Lic No. WMKA00301, AS3498 | |
| For one/several draw off points | Yes/Yes | Yes/Yes |
| Heating system | Bare wire | Bare wire |
| Electronic flow rate control | Yes | Yes |
| Electronic air detection system | Yes | Yes |
| Accepts pre-heated water (solar) | Yes (incoming hot water must not exceed 55°C) | |
| Programmable temperature | Yes | Yes |
CALCULATING OUTPUT WATER TEMPERATURE:
Add below temperature rise value to Seasonal Average incoming cold-water temperature to calculate output at a desired flow rate. Typical Basin or Sink Tap Flow Rate is 6 Lpm and a Shower 9 Lpm
DHE27 AU TEMPERATURE RISE (415 V) Litres Per Minute
DHE18 AU TEMPERATURE RISE (415 V) Litres Per Minute
6 Lpm +46°C. 8 Lpm +34°C. 10 Lpm +27°C. 12 Lpm +23°C. 14 Lpm +19°C
SEASONAL AVERAGE INCOMING COLD-WATER TEMPERATURES:
Melbourne: 15°C. Sydney/Brisbane/Perth/Adelaide: 18°C. Canberra/Hobart: 14°C. Townsville/Darwin: 25°C
Refer Download for Further Information & Water Temperature Output Calculations and Flow rates
5 Year full parts and labour domestic warranty*
*Conditions apply – refer Stiebel Eltron warranty policy for full details.
Must be installed by a qualified licensed person in accordance with manufacturer’s instructions and all relevant plumbing and electrical regulations.